<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Accepted and Presented Articles of OPSI Conferences</title>
<title_fa>مقالات پذیرفته و ارائه شده در کنفرانس‌های انجمن اپتیک و فوتونیک ایران</title_fa>
<short_title>ICOP &amp; ICPET _ INPC _ ICOFS</short_title>
<subject>Basic Sciences</subject>
<web_url>http://opsi.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1126-3278</journal_id_issn>
<journal_id_issn_online>10</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>7</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1395</year>
	<month>11</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2017</year>
	<month>2</month>
	<day>1</day>
</pubdate>
<volume>23</volume>
<number>مجموعه مقالات پذیرفته و ارائه شده در بیست و سومین کنفرانس اپتیک و فوتونیک ایران </number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>تله اندازی نوری در عمق با تنظیم طوقی تصحیح عدسی شیئی خشک</title_fa>
	<title>In-depth optical trapping by tuning correction collar of dry objective lens</title>
	<subject_fa>تخصصی</subject_fa>
	<subject>Special</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p&gt;&lt;span dir=&quot;RTL&quot; style=&quot;line-height: 20.7999992370605px; text-align: justify;&quot;&gt;انبرک نوری بهینه شده ابزاری بسیار مهم برای میکرودستکاری سیستم&#8204;های زیستی است. در این مقاله با استفاده از نظریه الکترومغناطیس&lt;/span&gt;&lt;span style=&quot;line-height: 20.7999992370605px; text-align: justify;&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;span dir=&quot;RTL&quot; style=&quot;line-height: 20.7999992370605px; text-align: justify;&quot;&gt;برداری ، توزیع فضایی شدت در کانون یک عدسی شیئی&lt;/span&gt;&lt;span style=&quot;line-height: 20.7999992370605px; text-align: justify;&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;span dir=&quot;RTL&quot; style=&quot;line-height: 20.7999992370605px; text-align: justify;&quot;&gt;خشک مورد استفاده در انبرک نوری و همچنین ثابت فنر منتجه محاسبه شده است. به دلیل وجود محیط&#8204;های متفاوت با ضریب شکست متفاوت در فضای پس از عدسی شیئی، مقدار قابل ملاحظه&#8204;ای ابیراهی کروی به وجود می&#8204;آید که باعث تضعیف شدید قدرت تله می&#8204;شود. در اینجا نشان داده&amp;shy;ایم که با تنظیم طوقی تصحیح عدسی شیئی بر مقادیر بیشتر از ضخامت لامل میکروسکوپ، می&#8204;توان ابیراهی کروی موجود را جبران و مقدار ثابت فنر تله&#8204;ی نوری را به بیشترین مقدار رساند. این تنظیم امکان به تله&#8204;اندازی در عمق دلخواه نمونه مورد مطالعه توسط انبرک نوری&amp;nbsp; را فراهم می&#8204;سازد&lt;/span&gt;&lt;span dir=&quot;RTL&quot; style=&quot;line-height: 20.7999992370605px; text-align: justify;&quot;&gt;.&lt;/span&gt;&lt;span style=&quot;line-height: 20.7999992370605px; text-align: justify;&quot;&gt;&amp;nbsp;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p&gt;&lt;span style=&quot;line-height: 20.7999992370605px; text-align: justify;&quot;&gt;Optimized optical tweezers&lt;/span&gt;&lt;span style=&quot;line-height: 20.7999992370605px; text-align: justify;&quot;&gt;re indispensable tools for micromanipulation for biological tissues. Using electromagnetic theory the spatial intensity profile at the&lt;/span&gt;&lt;span style=&quot;line-height: 20.7999992370605px; text-align: justify;&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;line-height: 1.6em; text-align: justify;&quot;&gt;&amp;nbsp;afocus of a dry objective lens and its trapping stiffness are calculated. Presence of mediums with different refractive indices after the objective introduces significant amounts of spherical aberrations, which degrades the strength of the trap. Here we have shown, that tuning the correction collar of the objective on a value larger than the thickness of the coverslip can compensate for this aberration, which in turn maximizes the trapping stiffness. This tuning possibility allows for trapping at desired depth of the sample under investigation with optical tweezers&lt;/span&gt;&lt;/p&gt;
</abstract>
	<keyword_fa>ابیراهی کروی, انبرک نوری, طوقی تصحیح عدسی شیئی خشک, عمق بهینه</keyword_fa>
	<keyword>Spherical aberration, Optical tweezers, Correction collar value of dry objective lens, Optimal depth</keyword>
	<start_page>445</start_page>
	<end_page>448</end_page>
	<web_url>http://opsi.ir/browse.php?a_code=A-10-1-1256&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Hossein</first_name>
	<middle_name></middle_name>
	<last_name>Gorjizadeh Alinezhad</last_name>
	<suffix></suffix>
	<first_name_fa>حسین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>گرجی زاده علی نژاد </last_name_fa>
	<suffix_fa></suffix_fa>
	<email>h_gorjizadeh@physics.sharif.ir</email>
	<code>10031947532846005213</code>
	<orcid>10031947532846005213</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه صنعتی شریف</affiliation_fa>
	 </author>


	<author>
	<first_name>Seyed Nader</first_name>
	<middle_name></middle_name>
	<last_name>Seyed Reihani</last_name>
	<suffix></suffix>
	<first_name_fa>سید نادر </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سید ریحانی </last_name_fa>
	<suffix_fa></suffix_fa>
	<email>sreihani@sharif.ir</email>
	<code>10031947532846005214</code>
	<orcid>10031947532846005214</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه صنعتی شریف</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
