<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Accepted and Presented Articles of OPSI Conferences</title>
<title_fa>مقالات پذیرفته و ارائه شده در کنفرانس‌های انجمن اپتیک و فوتونیک ایران</title_fa>
<short_title>ICOP &amp; ICPET _ INPC _ ICOFS</short_title>
<subject>Basic Sciences</subject>
<web_url>http://opsi.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1126-3278</journal_id_issn>
<journal_id_issn_online>10</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>7</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1399</year>
	<month>11</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2021</year>
	<month>2</month>
	<day>1</day>
</pubdate>
<volume>27</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>شناسایی آمونیوم نیترات در پوشش‌ پلی‌پروپیلن با استفاده از بیناب‌نمایی رامان عمیق</title_fa>
	<title>Detection of Ammonium Nitrate in Polypropylene container by employing Deep Raman Spectroscopy</title>
	<subject_fa>تخصصی</subject_fa>
	<subject>Special</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>یکی از محدودیت&#8204;های بیناب&#8204;نمایی رامان آشکارسازی اهداف دارای پوشش است. برای رفع این مشکل روش بیناب&#8204;نمایی رامان عمیق معرفی شده است. در این پژوهش آشکارسازی آمونیوم نیترات در پوشش پلی&#8204;پروپیلن با استفاده از روش&#8204;های مختلف رامان عمیق انجام شده است. بیشترین نسبت سیگنال به نوفه در طول موج شاخص آمونیوم نیترات (cm-11043) در روش&amp;nbsp;TR-SORS در زمان تاخیر ns160 و جابجایی mm4 ثبت گردید.</abstract_fa>
	<abstract>&lt;h1&gt;&lt;/h1&gt;
&lt;a name=&quot;OLE_LINK77&quot;&gt;&lt;/a&gt;&lt;a name=&quot;OLE_LINK76&quot;&gt;Marziyeh Hemati Farsani, Seyyed Hossein Amiri, Seyyed Mohammad Reza Darbani and Abolhasan Mobashery&lt;/a&gt;&lt;br&gt;
&lt;a name=&quot;OLE_LINK79&quot;&gt;&lt;/a&gt;&lt;a name=&quot;OLE_LINK78&quot;&gt;Optics and Laser Science and Technology Research Center, Malek-Ashtar University of Technology, Shahin-shahr&lt;/a&gt;&lt;br&gt;
&lt;a name=&quot;OLE_LINK11&quot;&gt;One of the limitations of Raman Spectroscopy is detection of concealed samples. To solve this problem, the Deep Raman spectroscopy has introduced&lt;/a&gt;&lt;a name=&quot;OLE_LINK14&quot;&gt;&lt;/a&gt;&lt;a name=&quot;OLE_LINK13&quot;&gt;.&lt;/a&gt; In this research, the detection of ammonium nitrate (AN) inside Polypropylene (PP) container has been successful by deep Raman. Maximum SNR of AN in 1043 cm&lt;sup&gt;-1&lt;/sup&gt; obtained by TR-SORS method with 160 ns delay time and 4 mm offset.</abstract>
	<keyword_fa>رامان عمیق, جابه‌جایی فضایی, تفکیک زمانی, آمونیوم نیترات, پلی‌پروپیلن</keyword_fa>
	<keyword>Deep Raman, Offset, Time Resolved, Ammonium Nitrate (AN), Polypropylene (PP)</keyword>
	<start_page>634</start_page>
	<end_page>637</end_page>
	<web_url>http://opsi.ir/browse.php?a_code=A-10-1-2424&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>مرضیه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>همتی‌فارسانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846009810</code>
	<orcid>10031947532846009810</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>پژوهشکده علوم و فناوری اپتیک و لیزر، دانشگاه صنعتی مالک‌اشتر، اصفهان</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>سیدحسین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>امیری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846009811</code>
	<orcid>10031947532846009811</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>پژوهشکده علوم و فناوری اپتیک و لیزر، دانشگاه صنعتی مالک‌اشتر، اصفهان</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>سید محمدرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>دربانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846009812</code>
	<orcid>10031947532846009812</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>پژوهشکده علوم و فناوری اپتیک و لیزر، دانشگاه صنعتی مالک‌اشتر، اصفهان</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>ابوالحسن</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مبشری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846009813</code>
	<orcid>10031947532846009813</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>پژوهشکده علوم و فناوری اپتیک و لیزر، دانشگاه صنعتی مالک‌اشتر، اصفهان</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
